Kohler K-T14491-4-BGD Installation Guide Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
4. Install the Trim K-T10424
Firmly press the valve stem adapter onto the valve stem.
Secure the valve stem adapter to the valve stem with the correct
length screw, as selected in the Install the Valve Stem Adapter
section of this guide.
Align the holes on the front plate assembly and the valve.
NOTE: Be sure to select the correct length screw for your
application.
Attach the two screws through the front plate assembly and into
the valve. Do not overtighten.
Visually inspect the front seal plate assembly to ensure that the
foam seal is completely covering the wall opening. If not, stop the
installation and repair the wall opening.
Place the escutcheon against the wall. The drain hole in the
escutcheon should face downward in the 6 o’clock position.
Thread the adapter ring onto the hub of the front plate assembly.
Place the handle assembly against the escutcheon by lining up the
pins in the handle assembly with the holes in the escutcheon.
Make sure the handle is in the 12 o’clock position and the
setscrew hole is facing down.
Tighten the setscrew in place with a hex wrench. Make sure the
handle assembly is tight against the escutcheon.
Valve Stem
Adapter
Screw
Transfer Valve
Escutcheon
Front Plate Assembly
Adapter
Ring
Handle
Assembly
Setscrew
Screws
Kohler Co. 7 1041514-2-K
Page view 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 27 28

Comments to this Manuals

No comments