Attach the Counterweights (cont.)
Check to make sure the counterweights are freely suspended and do not come in contact with the
receptor tray.
Raise and lower the door several times.
If the counterweights contact the receptor tray, make sure the cable is positioned over both pulleys.
IMPORTANT! The receptor tray and counterweights should not come in contact with one another. If they
are in contact, first make sure the cable is positioned on both pulleys. Then check if the cutout is too small
and the receptor tray is making contact with the subfloor. Remove the receptor tray, remove any
obstructions with the subfloor, and reposition the receptor tray as needed.
Check Operation
Raise and lower the door several times.
Make sure the wires do not contact the pulley cables.
If the counterweights contact the receptor tray, make sure the cable is positioned over both pulleys.
Make sure the counterweights function smoothly. They should not make any contact with the bath.
If the counterweights make contact with the bath, check to make sure the bath is level. Adjust level
as needed.