1. Determine the Layout
WARNING: Risk of property damage. Allow a minimum of 12 (30.5 cm) of air space around the
steam generator at all times. This provides an area for the heat generated by the unit to dissipate.
WARNING: Risk of personal injury. Do not install the Steam Control User Interface outside the
steam enclosure. The User Interface must be installed within the enclosure to allow the sensors to
regulate the temperature and control the flow of steam. Refer to the Installation Guide for the
Steam Control Kit.
NOTICE: When installing the control kit, allow room in the control cable for a drip loop. The drip loop
will discourage moisture from following the control cable to the steam generator.
NOTICE: The steam generator will perform best when installed as close as possible to the steam head. The
unit should be installed within 25’ (7.62 m) of the steam head.
NOTICE: For optimum performance install the steam generator below the level of the steam head.
NOTE: When possible, use 45 degree elbows. Performance will be increased when 45 degree elbows are
used.
Determine the location of the steam generator. Allow for a 12 (30.5 cm) air gap on all sides of the
generator. Allow for a drain pan.
Choose a drain pan appropriate for your installation. The drain pan is not supplied.
Tee
Steam Head
Control Cable Input
Pressure Relief Valve
Copper
Union
Shut-Off
Valve
Water
Inlet
Recommended
In-Line Water Filter
Front of Generator
(Access Panel)
Pitch toward generator.
Drain Pan
Install copper union as close
as possible to steam generator.
1053772-2-E 4 Kohler Co.