3. Determine the Location of the Steam Generator
IMPORTANT! The minimum required access panel is 24 (61 cm) L x 15 (38.1 cm) H. Allow for a
minimum 12 (30.5 cm) space around all sides of the steam generator.
Ensure clearance between the steam line and any surrounding surfaces.
Allow for access to the steam generator after installation.
Allow for a 12 (30.5 cm) air gap on all sides of the generator.
Allow for a drain or spill pan.
For optimum performance, install the steam generator below the level of the steam head and as
close as possible to the steam head. The steam generator should be installed within 25 ft (7.62 m) of
the steam head in a dry, well-ventilated area
4. Install the Electrical Supply
Model K-1696-NA K-1713-NA
Required Electrical Service
Generator Dedicated Circuit 13 kW, 240 V, 80 A, 50/60 Hz 15 kW, 240 V, 90 A, 50/60 Hz
Product Information
Weight 32 lbs (14.5 kg ) 32 lbs (14.5 kg )
Size 18 (45.7 cm) L x 12 (30.5 cm) x 13 (33 cm)
Electrical Rating 240 V, 59 A, 50/60 Hz 240 V, 68 A, 50/60 Hz
Water Supply 3/8 copper line 3/8 copper line
Water Supply Shut-Off Valve 3/8 NPT female 3/8 NPT female
Steam Line 1/2 copper line (1/2 NPT
thread)
1/2 copper line (1/2 NPT
thread)
17-3/4" (45.1 cm)
Steam Outlet
Water Inlet
11-3/4"
(29.8 cm)
3/4" NPT
Pressure Relief
Field Wiring
Service Box
8-3/8"
(21.3 cm)
12"
(30.5 cm)
Green LED
Diagnostic Light
Minimum required access panel is
24" (61 cm) L x 15" (38.1 cm) H.
Allow for a minimum of 12" (30.5 cm) of
space around all sides of the steam generator.
Allow for the Drain/Spill Pan.
3/4" (1.9 cm) Min
Control
Cable Input
1053772-2-E 6 Kohler Co.