5. Install the Steam Generator
WARNING: Risk of property damage. Allow a minimum of 12 (30.5 cm) of air space around the
steam generator at all times. This provides an area for the heat generated by the unit to dissipate.
NOTICE: For optimum performance, install the steam generator as close as possible to the steam head.
The steam generator must be installed within 25’ (7.62 m) of the steam head.
Install the desired drain pan at the steam generator location.
Position the steam generators on the support blocks.
Steam Outlet
Inlet
Maintain a 12" (30.5 cm) minimum
space around the units.
Pressure Relief Valve
Drain Pan
Control Cable
Input
1053772-2-E 8 Kohler Co.