3. Install the Temperature Sensor
IMPORTANT! Do not locate the temperature sensor directly above the steam outlet.
IMPORTANT! When installing the temperature sensor, allow room in the sensor wire for a drip loop. The
drip loop will discourage moisture from following the sensor cable to the steam generator.
Make sure that the power is turned off at the main breaker panel before proceeding.
Locate the temperature sensor on the wall 5 (12.7 cm) down from the ceiling.
At the selected location, drill a hole 3/8 (1 cm) in diameter.
IMPORTANT! Do not pinch, nail, wedge, or use undue force when handling the temperature sensor wire.
Any damage to the wire may result in temperature sensor failure. If the temperature sensor is not installed
immediately, protect the end connector with tape or other shielding material.
Insert the temperature sensor wire through the drilled hole.
Route the temperature sensor wire behind the wall to the steam generator. Connection to the steam
adapter to follow.
Apply a small bead of silicone sealant around the back side of the sensor housing where it will
contact the wall. Wipe off any excess sealant and do not let any sealant contact the sensor probe.
Press the sensor firmly onto the wall.
Temporarily secure the sensor in place with tape.
Allow the silicone sealant to cure before use.
5" (12.7 cm)
from Ceiling
3/8" (1 cm) D.
Apply silicone sealant.
Apply silicone sealant.
Back View
Temperature
Sensor
Drip Loop
Kohler Co. 7 1069332-2-C