5. Connect the Components
CAUTION: Risk of electric shock or product damage. Make sure the power cord is unplugged
before removing the access covers.
Low Voltage Connections Controls and Components
Note: For wireless applications an Ethernet connection is not needed.
Remove the low voltage access cover.
Remove the grommets in the locations where the cables will be installed. Refer to the Connection
Key.
Gently press each connection until it snaps together.
Slide the cable grommet into the slot with the male end up. Verify the grommet is properly seated.
High Voltage Connections Lights and Power
IMPORTANT! Use only copper wire for high voltage connections.
Remove the high voltage access cover.
If connecting a light, remove the knockout.
TIP: To remove the knockout, use a flat-blade screwdriver and gently tap with a hammer. Use care not to
damage the internal components.
Secure the cable to the media box using the watertight strain relief fitting provided.
Connect the wire for line, neutral, and ground according to the above illustration. Secure each wire
to the appropriate terminal.
Make sure power cord
is unplugged before
opening access covers.
1/2" (1.3 cm) D.
Knockout
Grommet
Male End
Slide grommet into slot
with male end up.
High Voltage
Access Cover
Low Voltage
Access Cover
Install grommets
flush with media box.
Indicator Light
Line
Neutral
Ground
Use copper
wire only.
Lighting Connection
1069763-2-D 10 Kohler Co.