4. Installation Checkout
Ensure that the valves are in the closed position. Turn the cold
valve fully counterclockwise. Turn the hot valve fully clockwise.
Turn on the main water supply.
Check the complete installation for leaks with the valves closed
and open.
Repair leaks as needed.
Close both valves and turn off the main water supply.
WARNING: Risk of personal injury. To prevent water spray,
wrap a cloth towel around the diverter before loosening the
diverter plug. Water will purge from the diverter when you
remove the diverter plug.
Wrap a cloth towel around the diverter, then carefully loosen the
diverter plug to remove pressure.
Retighten the diverter plug to the diverter.
Install a plaster guard (provided) over each valves and install the
cap (provided) over the diverter.
NOTE: Remove the cap from the diverter just before the spout from
the bath faucet trim will be installed.
Begin the bath faucet trim installation. Refer to the bath faucet
trim manufacturer’s instructions.
Close
Cold
Cap
Plaster Guard
Close Hot
Diverter
Plug