116570-2-AA (B)
1999 Kohler Co.
BEFORE YOU BEGIN
NOTES
Shut off the main water supply.
Inspect the supply tubing for damage. Replace
as necessary.
Observe local plumbing codes.
If possible, install this faucet before installing the
lavatory.
Kohler Co. reserves the right to make
revisions in the design of faucets
without notice, as specified in the Price
Book.
TOOLS AND MATERIALS RECOMMENDED
Adjustable wrench
Thread sealant
Plumbers putty
Hacksaw or tubing cutter
Pipe wrench
Channel lock pliers
INSTALLATION
FAUCET
Apply a ring of plumbers putty or other sealant to
the underside of the spout according to the putty
manufacturer’s instructions. Fit the spout
through the center lavatory hole.
Install the metal washer and nut, and securely
wrench tighten the nut.
Remove any excess putty or sealant.
Thread the shank nut about halfway up the spout
shank.
Nut
Apply Plumbers
Putty
Metal
Washer
Shank Nut
Remove and retain the guide tube nut and
O-ring from the supply tee.
Insert the plastic gasket and rubber washer into
the supply tee. Slide the metal washer on the
spout shank, and thread the supply tee to the
spout shank until hand tight.
Align the supply arms to the sides, and carefully
wrench tighten the hex end of the supply tee.
Thread the shank nut down against the supply
tee, and securely wrench tighten.
Slide a compression nut and ferrule onto each
supply arm.
Slip the O-ring over the guide tube, and wrench
tighten the guide tube nut to the supply tee.
Supply Tee
Spout Shank
O-Ring
Plastic Gasket
Guide
Tube Nut
Tee Hex-End
Rubber Washer
Metal Washer
Supply Inlet
Shank Nut
Guide Tube
Compression
Nut
Ferrule
WIDESPREAD
LAVATORY
FAUCETS
INSTALLATION
INSTRUCTIONS
Page view 0
1 2 3 4

Summary of Contents

Page 1

116570-2-AA (B)1999 Kohler Co.BEFORE YOU BEGINNOTES Shut off the main water supply. Inspect the supply tubing for damage. Replaceas necessary. O

Page 2 - DRAIN (CP AND PB FINISHES)

116570-2-AA (B)2Kohler Co., Kohler, WI Thread a locknut all the way onto each end bodyso the flat surface of the locknut faces the top of theend body

Page 3 - ALL DRAINS

3116570-2-AA (B)Kohler Co., Kohler, WIDRAIN (OTHER FINISHES) Remove the flange from the body. Thread the nut completely onto the body. Apply a 1/2”

Page 4 - INSTALLATION CHECKOUT

116570-2-AA (B)4Kohler Co., Kohler, WI Slide the faucet lift rod through the hole in thespout and through the hole in the link. Tighten the thumb sc

Comments to this Manuals