116637-2-BC
THERMOSTATIC MIXING VALVE TRIM
K-T9493, K-T9494
1. BEFORE YOU BEGIN
IMPORTANT INSTRUCTIONS
READ AND SAVE FOR THE CONSUMER
WARNING: Risk of scalding or other severe injury.
Before completing installation, the installer must set the maximum water temperature setting of this valve to
minimize the risks associated with scalding hazards according to ASTM F 444.
The installer is responsible for installing the valve and adjusting the maximum water temperature of this
thermostatic valve according to instructions.
This valve meets or exceeds ANSI A112.18.1M, ASSE 1016, and CSA B125.
If you do not understand any of the installation or temperature adjustment instructions in this document, in the United
States please contact our Customer Service Department at 1-800-4-KOHLER. Outside the U.S. please contact your
distributor.
IMPORTANT: Please fill in the blanks below and on the valve label. Then insert these instructions into the plastic
bag included with the valve package, and attach the plastic bag to the valve handle for the owner’s reference.
THIS DEVICE HAS BEEN PRESET BY ______________________ OF
_______________________ TO ENSURE A SAFE MAXIMUM TEMPERATURE.
ANY CHANGE IN THE SETTING MAY RAISE THE DISCHARGE TEMPERATURE
ABOVE THE LIMIT CONSIDERED SAFE, AND LEAD TO SCALDS.
DATE: _____________
CAUTION: Risk of scalding hazard. This device
has been calibrated at the factory to ensure a safe
maximum water temperature. Any variance in
settings or water inlet conditions from those used
during factory calibration may raise the discharge
temperature above the safe limit, and may present a
scalding hazard. Responsibility for installation and
adjustment of this device in accordance with these
instructions lies with the installer.
CAUTION: Risk of product damage. This valve
contains plastic and rubber components. Do not
apply excessive heat to the valve body when you
make solder connections. Do not apply flux or acids
directly to the valve, as damage to the seals, plastic
components, and trim finish may result. Do not apply
petroleum-based lubricants to the valve components,
as damage may result.
TOOLS AND MATERIALS REQUIRED
Thermometer
3/4” nominal copper tubing and fittings
Wrenches
Thin-blade knife or screwdriver
Thread sealant
Solder and flux
Hacksaw or tubing cutter
Silicone Sealant (optional)
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - K-T9493, K-T9494

116637-2-BCTHERMOSTATIC MIXING VALVE TRIMK-T9493, K-T94941. BEFORE YOU BEGINIMPORTANT INSTRUCTIONSREAD AND SAVE FOR THE CONSUMERWARNING: Risk of scal

Page 2 - ABOUT THIS VALVE

10116637-2-BCKohler Co., Kohler, WI U.S.A.

Page 3

11116637-2-BCKohler Co., Kohler, WI U.S.A.

Page 4 - 2. COMPOSITE LAYOUT

12116637-2-BCKohler Co., Kohler, WI U.S.A.In the U.S.A., call 1-800-4-KOHLERIn Mexico, call 001-877-680-1310In Canada, call 1-800-964-

Page 5 - 3. INSTALLATION

2116637-2-BCKohler Co., Kohler, WI U.S.A.ABOUT THIS VALVE The thermostatic mixing valve cartridge does notcontain an integral volume control/shut-off

Page 6 - ADJUST TEMPERATURE SETTINGS

3116637-2-BCKohler Co., Kohler, WI U.S.A.ROUGHING-IN – K-400-K WITH K-T9494-7Fig. #16-1/8” D.(15.6cm)1-9/16”(4cm)MIN.2-1/4”(5.7cm) MAX.4-13/16”(12.2cm

Page 7

4116637-2-BCKohler Co., Kohler, WI U.S.A.2. COMPOSITE LAYOUTFig. #3A. K-400 Thermostatic Mixer and K-T9494 TrimB. K-403 Volume Control and K-T9472 Tri

Page 8 - Counterclockwise

5116637-2-BCKohler Co., Kohler, WI U.S.A.3. INSTALLATIONCONSTRUCT FRAMING AND INSTALLROUGH PLUMBINGDetermine the desired location for the valve accord

Page 9 - (if needed)

6116637-2-BCKohler Co., Kohler, WI U.S.A.CAUTION: Risk of scalding hazard. Do not turn thethermostatic mixing valve stem after you adjust thetemperatu

Page 10 - Kohler Co., Kohler, WI U.S.A

7116637-2-BCKohler Co., Kohler, WI U.S.A.NOTE: Do not turn the thermostatic mixing valve stem atthis time. Turning the mixing valve stem will change t

Page 11

8116637-2-BCKohler Co., Kohler, WI U.S.A.INSTALL VOLUME CONTROL TRIM – K-401VALVERotate the volume control valve stem fully counterclock-wise.Press th

Page 12 -    

9116637-2-BCKohler Co., Kohler, WI U.S.A.COMPLETE TRIM INSTALLATION – ALLMODELSPress the mixing valve knob onto the mixing valve stemso the knob butto