16. Chromatherapy Light Operation
NOTE: These directions pertain to the use of the mounted control switch only. For more information, see
the Using the Remote Control section.
If the chromatherapy lights are turned off, press the button on the chromatherapy control switch
(located next to the pump control switch). The chromatherapy lights will begin to cycle through
each of the colors (sweep mode).
When the chromatherapy lights are in sweep mode, you can lock in one color light by pressing the
chromatherapy control switch.
When an individual color is locked in, press the chromatherapy control switch to turn the
chromatherapy lights off.
17. Troubleshooting Procedures
For warranty service, contact your dealer or wholesale distributor. This Troubleshooting Guide is for general
aid only. Contact a Kohler Authorized Service Representative or a qualified electrician to correct all electrical
problems. For warranty service, contact your dealer or wholesale distributor.
Symptoms Probable Causes Recommended Action
1. Green light in On/Off
control switch flashes
before the bathing well is
full of water.
A. Spout fills directly into overflow
channel.
A. Adjust/reinstall the spout to fill
directly into the bathing well.
Refer to the installer/dealer.
B. One or both butterfly valves do
not work.
B. Check the butterfly valve wiring
or replace the butterfly valves.
Refer to the installer/dealer.
C. Control does not work. C. Check the wiring or replace the
control. Refer to the
installer/dealer.
2. Product does not start. A. No power to unit. A. Turn on the power to the unit, or
correct the source of the power
loss. Refer to the installer/dealer.
B. Water does not cover the overflow
channel sensors.
B. Fill the bathing well until water
flows over the bathing well rim,
into the overflow channel, and
covers the overflow channel
sensors. Suggested fill level is to
the drain overflow.
C. On/Off control switch does not
light up or flash when the unit is
running or filled as required.
C. Check the wiring or replace the
On/Off control switch. Refer to
the installer/dealer.
D. Pump/motor does not work. D. Rebuild or replace the
pump/motor. Refer to the
installer/dealer.
E. Control does not work. E. Check the wiring or replace the
control. Refer to the
installer/dealer.
3. Water does not cascade
evenly over the entire
bathing well rim.
A. Unit is not level. A. Level the unit by using the
wrench provided to turn the
adjustable feet up or down as
needed.
B. Bathing well ports are blocked. B. Remove blockage.
C. Metal suction screen is blocked. C. Clean the metal suction screen.
4. Unit stops automatically
before 18 minutes.
A. GFCI/ELCB trips. A. Identify the source of the fault
and correct. Refer to the
installer/dealer.