Troubleshooting (cont.)
Airjet System Troubleshooting Table
Symptoms Probable Causes Recommended Action
1. Blower motor will not
start.
A. Power cord from blower motor
to control is loose, disconnected,
or damaged.
A. Check wiring for proper
connections.
B. User interface cable connections
are loose or damaged.
B. Inspect the cables between the user
interface, heated surface control,
bubble control, and control
amplifier. Secure connections or
replace cables as needed.
C. Bubble control does not work. C. Replace the bubble control.
D. Blower motor does not work. D. Replace the blower motor.
2. Blower motor stops
running and will not
immediately restart.
A. Blower motor overheated and
protection device activated.
A. Check for blockage at air inlet.
Remove blockage and allow motor
to cool. Refer to Blower motor will
not start.
3. Blower motor starts, some
but not all airjets are
bubbling.
A. Blower motor speed is too low. A. Increase speed set point to blower
motor.
B. Blower air inlet is blocked. B. Clear blower air inlet.
C. Blower motor does not work. C. Replace the blower motor.
D. Blower motor discharge is
blocked.
D. Clear blockage.
E. Check valve does not work. E. Replace the check valve.
F. Airjets are clogged. F. Use a small between-the-teeth
dental brush and white vinegar.
Dip the brush in the vinegar, brush
the hole, rinse the brush in clean
water, and then use the wet rinsed
brush to rinse the hole.
G. Some zones are closed. G. Operate all zones.
4. Blower motor runs but no
air bubbles are formed.
A. Blower air inlet is blocked. A. Clean blower air inlet.
B. Airjets are clogged. B. Use a small between-the-teeth
dental brush and white vinegar.
Dip the brush in the vinegar, brush
the hole, rinse the brush in clean
water, and then use the wet rinsed
brush to rinse the hole.
C. Check valve does not work. C. Replace the check valve.
D. Bubble control does not work. D. Replace the bubble control.
E. Blower motor does not work. E. Replace the blower motor.
5. Blower motor operates,
air bubbles are formed,
zone controls work, but
variable speed feature
does not work.
A. Blower air inlet is blocked. A.
Clear blower air inlet.
B. Loose, disconnected, or
damaged wiring harness.
B. Check wiring for proper
connections. Replace the wiring
harness if necessary.
C. Bubble control does not work. C. Replace the bubble control.
D. Blower motor does not work. D. Replace the blower motor.
E. User interface does not work. E. Replace the user interface.
6. Blower motor won’t turn
off when the power icon
on user interface is
touched.
A. Loose, disconnected, or
damaged wiring harness.
A. Check wiring for proper
connections. Replace the wiring
harness if necessary.
B. Bubble control does not work. B. Replace the bubble control.
C. User interface does not work. C. Replace the user interface.
1212241-2-A 18 Kohler Co.