Installation Instructions
WARNING: When using electrical products, basic precautions should always be followed,
including the following:
DANGER: Risk of electric shock. Connect only to a circuit protected by a Ground-Fault
Circuit-Interrupter (GFCI)*.
Install to permit access for servicing.
A pressure wire connector marked Earth/Ground is provided within the wiring compartment. To reduce
the risk of electric shock, connect this connector to the grounding terminal of your electric service or supply
panel with copper wire equivalent in size to the circuit conductor supplying this equipment.
A pressure wire connector is provided on the exterior of the pump or control within this unit to permit
connection of a bonding conductor between this unit and all the other exposed metal in the vicinity, as
needed to comply with local requirements.
Grounding is required. The unit should be installed by a qualified service representative, and grounded.
WARNING: Risk of injury or property damage. Please read all instructions thoroughly before
beginning installation, including the following requirements.
WARNING: Risk of electric shock. A qualified electrician should make all electrical connections.
WARNING: Risk of electric shock. Disconnect power before servicing.
NOTICE: Follow all local plumbing and electrical codes. In Canada, install this unit in accordance with
the Canadian Electrical Code, Part 1.
*Outside North America, this device may be known as a Residual Current Device (RCD).
Product Information
Electrical Requirements
WARNING: Risk of burns, fire, electric shock, or injury. Do not operate the heater if the power
supply cord is damaged. For proper guidance to have this product repaired, please call:
1-800-4KOHLER from within the USA or Canada, or 001-800-456-4537 from within Mexico.
The installation must have a Class A Ground-Fault Circuit-Interrupter (GFCI)*. The GFCI protects against
line-to-ground shock hazard. Use a 120 V, 15 A, 60 Hz dedicated service for the bath.
If the blower supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
NOTICE: For -G2MW Music Models: This installation requires installation of an electrical outlet within
24 (610 mm) of the amplifier location. Refer to the amplifier installation instructions.
*Outside North America, this device may be known as a Residual Current Device (RCD).
Product Notices
NOTICE: Keep the area around the blower clean and free of debris. Ensure that the area around the
blower is free of sawdust, insulation, dirt, and other small loose debris. Such material can block the blower
air ducts and reduce the air flow through the blower.
NOTICE: This product contains an automatic water purge mode that turns the blower on for 2 minutes
about 30 minutes after the unit is turned off and drained.
1237792-2-E 2 Kohler Co.