5. Make the Electrical Connections Canada
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing
the following procedures.
WARNING: Risk of electric shock. Connect the blower motor to a properly grounded,
grounding-type Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). This
will provide additional protection against line-to-ground shock hazard.
Locate and secure each supplied junction box a minimum of 1-1/2 (38 mm) above the subfloor.
The bath controls and system have been prewired at the factory. A qualified electrician should make
a routine service connection to the junction box.
Connect service to the junction box. The 60 Hz model junction box contains line (black) and neutral
(white) wires and a ground lug.
A 120 V, 15 A dedicated circuit is required. Provide a Class A GFCI or RCD.
Provide a separate equipment grounding conductor for the inside ground or ground lug. The
conductor must not be connected to any current-carrying conductor.
Bond in accordance with national and local codes.
NOTICE: For -G2MW Music Models: Refer to the installation instructions included with the amplifier for
wiring and installation details. Position the amplifier anywhere within the shroud or in a remote location.
If installed within the shroud, the amplifier will need to remain plugged into the electrical outlet at all
times.
Blower Motor
Electrical Cord
Wire Connectors
Provide suitable
strain relief.
Wire the junction box as shown.
Line (Black)
Ground
From Blower
Neutral (White)
Supply from
Branch
Circuit Box
Ground
From Bask
Power Supply
Bask Power
Supply Cord
Junction
Box