6. Flush the Piping
Disassemble the valve as shown to remove the internal
components.
Slowly open the water supplies to run water through the supply
piping and valve body to remove any debris.
Inspect the two inlet seals of the pressure balancing unit (PBU). If
the seals are damaged, replace them with the provided extra inlet
seals. Lubricate the seals using the capsule provided.
To reinstall the PBU, push it into the valve in the initial install
position with the nuts on the PBU toward the hot inlet. Make
sure the PBU seals do not come in contact with the inlet/outlet
holes during initial installation because their rough edges may
damage the seals.
Rotate the PBU counterclockwise while applying downward
pressure until it is seated in the seating indents on the bottom of
the valve. The PBU should not rotate when it is properly seated.
Reassemble the remaining valve components as shown.
PBU InstallationValve Assembly
Pressure
Balancing Unit
PBU
Valve
Valve Cap
Valve
Stop
Stop
Cover
Screw
Screw
Water
Outlet Hole
Initial Install
Position
Final Install
Position
Kohler Co. 9 1150733-2-A