These instructions are to be left with the user
Installation and User Guide
SHOWER VALVE
BUILT IN DUAL CONTROL
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - BUILT IN DUAL CONTROL

1These instructions are to be left with the userInstallation and User GuideSHOWER VALVEBUILT IN DUAL CONTROL

Page 2 - CONTENTS

10INSTALLATIONGeneralInstallation must be carried out in accordance with these instructions, and must beconducted by designated, qualified and compete

Page 3 - SAFETY : WARNINGS

11Installation MethodsThe Discovery Thermostatic Shower Controlcan be installed using Rear Fixing Pointson the Body, or by using the SecuringBrackets

Page 4 - PACK CONTENTS

121. Solid Wall or Stud Partition(Using Securing Brackets - Mounting off Front Face)1.1 Remove the three securing screws andremove the shower valve fr

Page 5 - DIMENSIONS

131.7 Fit the three securing brackets to theshower valve.Important! Make sure that the correctholes are used, otherwise thebackplate will not fit (ref

Page 6 - SPECIFICATIONS

141.14 Re-fit the building-in shroud to the shower valve using the three fixing screws.1.15 Using the building-in shroud as a guide for the finished w

Page 7

152. Solid Wall or Stud Partition(Using Rear Fixing Points on Shower Control)2.1 Refer to section: ‘1. Solid Wall orStud Partition Installation (Using

Page 8 - INSTALLATION REQUIREMENTS

162.3 Mark the positions of the fixing screwholes on the wall.2.4 For solid walls drill two 6 mm holes forthe wall plugs.2.5 Fit the wall plugs (suppl

Page 9 - Flow Regulator Recommended

17Note! For laminated panels the showervalve must be positioned from the rear ofthe panel.Panel thickness must be between 4 and22 mm (if a thicker pan

Page 10 - INSTALLATION

183.6 To assist in marking the positions ofthe fixing holes, reverse the showervalve and fit the building in shroudthrough the cutout in the front of

Page 11 - Warning! Bottom bracket not

19Control Assembly1. Pull off the temperature knob.2. Carefully separate the concealing platefrom the backplate.Note! Use a screwdriver in the cutoutt

Page 12

2CONTENTSIntroduction ... 3Safety : Warnings ...

Page 13

20Push up and Latchover the Top of theBackplateAlign Flow Leveras Shown‘Click’ into Position5. Align the flow control lever so that thelever is pointi

Page 14

21Reversed SuppliesThe Discovery Dual Control is supplied with inlet connections Hot-Left, Cold-Rightand Top-Outlet as standard. If the hot and cold w

Page 15

22COMMISSIONINGMaximum Temperature SettingThe Thermostatic Shower Controls are preset at approximately 43 °C at the factory.If adjustment is required,

Page 16

23OPERATIONNote! If excessive flow rate is experienced from the Shower Control, install the suppliedFlow Regulator, refer to the Discovery Fittings In

Page 17

24FAULT DIAGNOSISSYMPTOM1. Only hot or coldwater from the controloutlet.2. Fluctuating or reducedflow rate.3. No flow rate from thecontrol outlet.4. B

Page 18 - M5 Fixing

25‘O’ KeySupply FilterMAINTENANCEGeneralThis Product is precision engineered and should give continued safe and controlledperformance, provided:1. It

Page 19

26SPARE PARTS1609.040 (A) Thermostatic Cartridge Assembly1609.041 (B) Elbow Pack (2 off)1609.042 (C) Flow Control Assembly1609.043 (D) Flow Contro

Page 20

27JABCC, K, JDDDEGIL K, J

Page 21

287-#51058366-W2-A(1609)© Kohler Mira Limited, February 2006CUSTOMER SERVICE

Page 22 - COMMISSIONING

3This Discovery Thermostatic Shower Control is precision engineered and should givecontinued safe and controlled performance, provided:1. It is instal

Page 23 - OPERATION

4 1 x Control Assembly Tick the appropriate boxes to familiarize yourself with the Discovery ThermostaticShower Control part names and to confirm t

Page 24 - FAULT DIAGNOSIS

5DIMENSIONSNote! All Dimensions are NominalPipe Centres186 mm47 mm 64 - 82 mm108 mm231 mm27 mm

Page 25 - MAINTENANCE

6SPECIFICATIONSPressuresMaximum Static Pressure: 10 Bar.Minimum Maintained Pressure (Gas Water Heater): 1.0 Bar.(for optimum performance initial suppl

Page 26 - SPARE PARTS

7ConnectionsStandard connections are: Hot-Left, Cold-Right, Top-Outlet, if reversed inlets arerequired refer to sections: ‘Installation’ and ‘Reversed

Page 27

8Flow Regulator RecommendedINSTALLATION REQUIREMENTSIsolating valveMixing ValveTwin Impeller PumpTempering ValvePressure Reducing ValveSingle Impeller

Page 28 - CUSTOMER SERVICE

9Flow Regulator RecommendedFlow Regulator RecommendedUnvented mains pressure systemThe shower can be installed with aunvented, stored hot water cylin