5. Remove the Pulley Assemblies and Mounting Brackets
Installations Requiring Disassembly Only
Disassembly Checkpoint #2
The steps below may not be necessary. Make sure removing the pulley assemblies,
mounting brackets, and/or drip tray is required. The bath can sometimes be moved into
place after the door is removed.
If the bath can be moved into place without removing the pulley assemblies, mounting
brackets, and/or drip tray, go directly to Position the Bath.
IMPORTANT! Save and organize all screws and hardware. All parts will be reused.
Remove the Pulley Assemblies
Disconnect the limit switch wires at the top of the pulley assemblies on both sides of the bath.
Remove the four red screws from the drain side of the bath. Take care not to strip the screw heads.
Remove the pulley assembly from the drain side of the bath.
Apply masking tape to the drain side pulley assembly and label it with the side it was removed
from. It must be reinstalled on the drain side of the bath.
Remove the four red screws from the other side of the bath. Take care not to strip the screw heads.
Remove the pulley assembly from the other side of the bath.
Remove the Mounting Bracket
Remove the four blue screws from the drain side of the bath. Take care not to strip the screw heads.
Remove Pulley Assemblies
Remove Mounting Brackets
Red Screw
Blue
Screw
Pulley
Assembly
Mounting
Brackets
Limit Switch