Kohler K-1913-R-96 Installation Guide Page 34

  • Download
  • Add to my manuals
  • Print
  • Page
    / 136
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 33
Troubleshooting Procedures (cont.)
It is normal to hear the compressor run for up to 90 seconds after the door is raised. The
compressor is located inside the door and is inflating the door seal.
If the door is fully raised for more than 20 minutes when there is no water in the bath,
the seals will automatically deflate.
It is normal to hear the solenoid valve, located inside the door, open and expel air when
the water level falls below the sensors. The valve is deflating the door seal.
Water coming from the bottom of the door and entering the drip tray is normal when it is
caused by the bather moving about in the bath when it is completely full. Excessive
splashing will cause water to run over the top of the inflated seals into the drip tray.
Water dripping into the drip tray as the seals deflate is normal. Water collects on the seal
during use and runs into the drip tray when the seals deflate.
Symptoms Probable Causes Recommended Action
1. Door is difficult to raise or
lower.
A. One or both counterweights are
not attached.
A. Reattach the counterweight(s).
B. One or both of the
counterweight cables are not fed
through the pulleys.
B. Use the provided tool to run the
counterweight cable onto the
pulleys.
C. The bath was not leveled
properly causing counterweights
to rub.
C. Level the bath.
D. Mounting bracket is not
adjusted properly.
D. Reduce the pressure on the door by
adjusting the mounting brackets
outward using the slots.
E. Door is rubbing against the bath
or access panel.
E. Adjust the door outward using the
slots in the pulley assembly. If
necessary adjust the access panel
brackets.
F. A roller is damaged or has
fallen off.
F. Replace the roller.
G. There is excessive wear on the
latch pin and/or strike plate.
G. Apply a drop or two of oil to the
face of the strike plate, replace the
strike plate, or call the Customer
Care Center using the information
provided on the back page of this
manual.
2. Door shimmies or shakes. A. Mounting bracket needs
adjustment.
A. Adjust one or both of the mounting
brackets inward using the slots,
until it is snug against the rollers.
3. Water is leaking/running
from accumulator.
A. This may occur with normal
operation.
A. See the Normal Operation
Includes portion of the
Troubleshooting Procedures.
B. Water supply connection is
loose or damaged.
B. Reseal the water inlet connections
and/or reconnect them.
C. Accumulator fitting(s) are loose
or disconnected.
C. Replace the accumulator connection
fitting(s).
D. Accumulator drain hose is
disconnected or leaks.
D. Reconnect or tighten the
accumulator drain line connection.
4. Bath will not fill all the
way to overflow.
A. The water supply connection is
loose or damaged.
A. Reseal the water inlet connections
and reconnect them.
B. Toe tap drain does not close or
is leaking.
B. Clean the toe tap assembly. Reseal
and reattach the drain. Replace if
needed.
1128532-2-C 34 Kohler Co.
Page view 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 135 136

Comments to this Manuals

No comments