Troubleshooting Procedures (cont.)
Symptoms Probable Causes Recommended Action
F2. If the error code is still activated,
unplug the power and call
Customer Care Center using the
information provided on the back
page of this manual.
G. The controller is not working. G. Replace the controller or call the
Customer Care Center using the
information provided on the back
page of this manual.
12. Noisy operation. A. After filling the bath, water
drains from the accumulator
into the drip tray drain. This
will create noise.
A. See the Normal Operation
Includes portion of the
troubleshooting.
B. The bath is not leveled properly
and counterweights are making
contact.
B. Check the back ledge and the sides
of the bath for level. Adjust the feet
until the bath is level if needed.
Check counterweight clearance.
C. The counterweight
guide/guides are not in place.
C. Reinstall the counterweight guides
in the correct position.
D. The compressor is making
excessive noise.
D. Call the Customer Care Center
using the information provided on
the back page of this manual.
13. Discoloration is observed
on the front of the bath.
A. Water is splashing over the top
of the seal.
A. Lower the water level when filling
the bath. Periodic cleaning of the
bath face is normal.
B. Door panel is rubbing against
the bath.
B. Adjust the door outward using the
slots in the pulley assembly.
14. Water is seen or heard
during or after filling the
bath.
A. During normal operation, it is
normal for water to discharge
from the accumulator drain hose
or for small amounts of water to
spill over the seals and run
down to the drip tray.
A. See the Normal Operation
Includes portion of the
troubleshooting.
B. Accumulator attachment is
damaged or leaks.
B. Reconnect or tighten the
accumulator drain line connection.
C. Water is splashing over the top
of the seal.
C. Lower the water level when filling
the bath. Reduce sudden
movements while bathing.
D. The door gap is too big because
the pulley assembly is not
properly adjusted.
D. Adjust the pulley assembly inward.
E. The primary seal system is not
operating properly.
E. Call the Customer Care Center
using the information provided on
the back page of this manual.
F. The secondary seal systems are
not operating properly.
F. Call the Customer Care Center
using the information provided on
the back page of this manual.
15. The bath will fill to the
overflow, but fails to
maintain its water level.
A. Toe tap drain is open, does not
close, or is leaking.
A. Close and/or clean the toe tap
assembly. Reseal and reattach the
drain. Replace if needed.
B. One or both of the limit
switches are not making contact
or are damaged.
B1. Adjust the limit switch/switches
until contact is made.
B2. The limit switch/switches need to
be replaced. Call the Customer
Care Center using the information
provided on the back page of this
manual.