A
"A" Mark
Cut Line
1/16"
(2 mm)
Threshold
A
Tape Measure
x2
U-Channel
x2
1/4-20 X 1/2"
Bracket
Gasket
Front
Plate
L-Bracket
Seal
Label
5/32"
1/4"
(6 mm)
Top View
Threshold
Showerhead
Side
Wall
1
2
3
U-Channel
Pivot Side
Outside of
Shower
Insert
U-Channel
Side View
U-Channel
Side View
Sealant
Sealant
Tin Snips
32 Teeth Per Inch Blade
Masking Tape
100% Silicone Sealant
Rubber Mallet
5/16" Masonry
Bit for Tile
5/16"
3/32", 1/8", 5/32"
Pivot Shower Doors
Hardware Skin Pack
1224634**
Hardware Skin Pack
Threshold
1224128-01**
Screw
1048208-C
Screw
1048208-D
1077762
Anchor
1222601-01**
Wall Jamb
Wall Seal
1223352-01
Bulb Seal
1070676-03**
Screw
1048208-AB
Door Seal
Strike Jamb Cap
1070675-03**
Strike Jamb
1223081-01**
Spacer
1224612**
U-Channel
1224903-01**
Plug
1223355-1
8-18 X 1-1/2"
8-18 X 5/8"
8-18 X 7/8"
Fixed Panel
1222162-01**
Slide Kit
1226627**
Hinge Kit
1226628**
Wall Mount
Bracket Kit
1226599**
Door Panel
1222166-02**[31" (787 mm)]
1222162-01**
[36" (914 mm)]
1227321**
Hardware Skin Pack
1224326**
1223351-01
Service Seal
(Not Included)
1013487-03
1223351-02
[28-5/16" (719 mm)]
[23-5/16" (592 mm)]
Top View
Showerhead
Strike Side
Handle
Pivot Side
Right Pivot
Top View
Showerhead
Strike Side
Pivot Side
Handle
Left Pivot
x2
Plug
8-18 X 1-1/2"
Seal
WARNING: Risk of serious injury. Damage prior to
installation can result in glass shattering. Inspect the
glass and all parts for damage before installation.
WARNING: Risk of serious injury. Improper installation
can result in glass shattering. Follow all installation
instructions.
NOTICE: Do not touch the edges of the tempered glass with
tools or any other hard objects. Do not set the unframed
tempered glass directly on the floor or any hard surface.
WARNING: Risk of serious injury. Do not cut tempered
glass. Tempered glass will shatter if cut.
WARNING: Risk of serious injury. Shower door and side
panels can shatter. Regularly inspect the glass and all parts
for damage, missing, or loose parts.
WARNING: Risk of serious injury. Always wear safety
glasses while cutting and drilling.
IMPORTANT: Leave this manual for the end user.
Read these instructions before installing or using this product.
Keep these instructions in a safe location for future reference.
These instructions can also be found at www.kohler.com
Pivot Shower Door
K-R709032, K-R709033
• Walls must be within 3/8” (10 mm) of plumb. This unit will
not function properly if the walls are more than 3/8” (10 mm)
out-of-plumb.
• Cover the drain with tape to avoid loss of small parts.
• Follow the silicone sealant manufacturer’s instructions for
application and curing time.
• Perform this installation with two people.
Determine which side of the door will open. A right
side pivot is shown below. The handle installs on the
showerhead side and the pivot installs on the side
opposite the showerhead.
Left side pivot shown below. A left side pivot is shown
throughout the instructions. The handle installs on the
showerhead side and the pivot installs opposite the
showerhead.
Measure distance “A.” Mark and cut the threshold
1/16” (2 mm) or the width of a saw blade less than “A.”
Position the threshold 1/4” (6 mm) from the front of
the ledge. Mark the location. If needed, file the ends
to match the corners and remove burrs. Remove the
tape cover and install the threshold on the ledge, tight
against the wall with the showerhead.
Confirm the black insert is in place in the U-channel. If
needed file the end of the U-channel to align with the
corner wall contour. Install the U-channel on the pivot
side of the threshold.
Position the bracket gaskets, #1222949, on the L-bracket
and front plate. Confirm the gaskets are correctly
oriented. On the side opposite the Clean Coat label,
position the L-bracket. Install the front plate to the fixed
panel and secure. Install the clear plastic seal, leaving a
1/2” (13 mm) gap at the bottom.
With a partner, position the fixed panel in the
U-channel. Plumb the fixed panel using a level.
Confirm the L-brackets are level. Mark the locations
of the four L-bracket screw holes with a nail or other
sharp object, using the bracket holes as a template.
Remove the fixed panel.
At each of the four marks, drill 5/16” holes with a drill
bit appropriate for the wall material. Install anchors
in each hole. Clean the surface of the shower to avoid
damage.
Apply silicone sealant along the entire length on the
inside of the U-channel.
Install the fixed panel in the U-channel. Loosely secure
the L-brackets to the wall. Level the brackets and fixed
panel. Tighten the screws while maintaining level. Press
the plug into the U-channel end. Adjust the seal tight
against the wall to cover any gaps.
11220848-2-A
USA/Canada: 1-800-4KOHLER
México: 001-800-456-4537
www.kohler.com
1220848-2-A
Installation and Care Guide
*Call the Customer Care Center to order replacement parts.
**Finish/color code must be specifi ed when ordering.
Retain this document for future servicing.
Record model number from box for reference.
Model Number:______________
Required Tools Parts Identifi cation
2 3 4
7 8
6
9
1
5
10
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - Model Number:______________

A"A" MarkCut Line1/16" (2 mm)ThresholdATape Measurex2U-Channelx21/4-20 X 1/2"BracketGasketFront PlateL-BracketSealLabel5/32"1

Page 2 - Troubleshooting

WarrantyONE-YEAR LIMITED WARRANTYKOHLER plumbing products are warranted to be free of defects in material and workmanship for one year from date of in

Page 3 - Nº du modèle:______________

AMarque "A"Ligne de découpe1/16" (2 mm) SeuilAMètre rubanx2Profilé en Ux21/4-20 x 1/2"Joint statique de support Plaque avant Suppo

Page 4 - Dépannage

GarantieGARANTIE LIMITÉE D'UN ANLes produits de plomberie KOHLER sont garantis contre tout vice de matériau et de fabrication pendant un an à par

Page 5 - Puerta pivotante de ducha

AMarca "A"Línea de corte1/16" (2 mm) UmbralACinta para medirx2Canal en Ux21/4-20 X 1/2"Empaque de soporte Placa frontal Soporte en

Page 6 - Guía para resolver problemas

GarantíaGARANTÍA LIMITADA DE UN AÑOSe garantiza que los productos de plomería KOHLER están libres de defectos de material y mano de obra durante un añ

Comments to this Manuals

No comments