Kohler Freewill Barier Free Bath Whirlpools K-12106-H User Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
*64-3/4”
56”
18”
13”
37”
7/8”
ELBOW
SUPPLY
4”
3/4”
2-7/8”
1-1/2” O. D.
C
L SPOUT
3”
19”
*84”
3”
1-5/16”
9”
5” 20”
4”
PUMP/CONTROL ACCESS
4
115982-2-BA (-)
Kohler Co., Kohler, WI
1. ROUGHING-IN: K-12105-H*, K-12106-H*
A. ORDERING INFORMATION
Applicable product:
Left outlet K-12105 shown
Right outlet K-12106 not shown
Accessories/hardware:
Drain K-7161-AF recommended
Jet trim kit K-9696 required
MasterShower
Handshower
K-9500 recommended*
Paladar valve only trim K-T14542-4 recommended
Paladar Rite-Temp valve K-304-K recommended
Bath spout K-6855 recommended
Dome light K-1570 optional
Glassworks bypass door
or
Forum bypass door
K-9864
K-703012
optional
* Dimensions illustrated
B. REQUIRED ELECTRICAL SERVICE
Dedicated branch circuit required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control 120 V, 20 A, 60 Hz
C. PRODUCT INFORMATION
ADA compliant
Fixture*: basin area top area weight
Bathing well 44” x 23” 51” x 26” 265 lbs.
water depth capacity
To overflow 13” 55 gals.
Configuration 1-piece
Drain Outlet 2-1/4” D.
* Approximate measurements for comparison only.
Pump high HP low HP V Hz A
2-speed 1 1/8 120 60 16.5
D. INSTALLATION NOTES
Read the entire installation instruction before beginning the
installation.
Unit is not drilled for supply fittings.
Shimming may be required to level fixture.
For optimum accessibility, specify faucets and fittings to
install and operate within the control area shown.
Pump is supplied with a grounding-type plug-in cord. Locate
the outlet behind the whirlpool, and within 24” of the pump.
ROUGHING-IN NOTES
Fixture conforms to ANSI Standard Z124.2. All dimen-
sions are nominal.
* Recess opening must be 65” x 84-1/4”.
No change in measurements if connected with drain il-
lustrated.
Minimum access panel:
Pump/control 20” W x 15” H required
Stud opening tolerance (+ 1/4” – 0”). When fire rated
wall is specified, dimensions are to the inside of the wall
board. Some shimming between stud frame and fixture
may be required.
Provide clear floor space per ANSI A117.1, and as
shown.
Represents control area for faucets.
Represents 24” wall mount slide bar.
36”
60”
Represents clear floor space for 36”
x 60” side entrance.
48”
60”
Represents clear floor space for 48”
x 60” side entrance.