Install the Waterway
1. Insert the concealing plate into the opening. The double ribs of the leak shields
should be facing up.
2. If any of the leak shields make contact with an elbow, make sure
that you enlarge the hole in the back of the leak shield t o
32 mm.
Install the Pipe Nipples
1. Remove the pipe nipples.
Note! The minimum distance between the face of the tees/elbows and the
surface of the finished ceiling should be 57 mm. The measurement for typical
installations is 70 mm.
2. Measure the distance from the face of the tees/elbows to the surface of the
finished ceiling. Make any adjustments as needed.
3. Install the nipples into the tee/elbows hand tight.
4. Measure the distance form the end of the nipples to the surface of the finished
ceiling. Make sure that the distance is at least 38 mm and no more than
44 mm.
5. If necessary, cut the G½” pipe nipples to length. Debur the ends.
6. Remove the nipples.
7. Apply thread sealant to the ends of the nipples and re-install the nipples to the
tees/elbows.
8. Run water through the system to flush out any dirt or debris.