7. Make the Electrical Connections Canada
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing
the following procedures.
WARNING: Risk of electric shock. Connect the junction box to a properly grounded,
grounding-type Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). This
will provide additional protection against line-to-ground shock hazard.
NOTICE: The control amplifier is equipped with a cord and plug. A qualified electrician must install a
GFCI- or RCD-protected, 120 V, 15 A grounded outlet. The junction box mounted to the bath must be
hard-wired to a GFCI- or RCD-protected, 120 V, 15 A service. The junction box and control amplifier may
share the same electrical service, but no other load should be on this circuit.
Install a 120 V, 15 A grounded outlet within the wall framing and within 24 (610 mm) of the
planned control amplifier location. Route the wires through conduit for this outlet installation.
Connect service to the junction box. The junction box contains line (black) and neutral (white) wires
and a ground lug.
A 120 V, 15 A dedicated circuit is required. Provide a Class A GFCI or RCD.
Provide a separate equipment grounding conductor for the inside ground or ground lug. The
conductor must not be connected to any current-carrying conductor.
Bond in accordance with national and local codes.
Control
Amplifier
24" (610 mm)
Maximum
Conduit
120 V, 15 A
Grounded Outlet
Provide
suitable
strain relief.
Wire the junction box as shown.
Line (Black)
From Bubble
Power Supply
From Blower
Wire Connectors
Supply from
Branch Circuit Box
Ground
From Bask
Power Supply
Neutral (White)