1. Install an Electrical Outlet
WARNING: Risk of electric shock, fire, or personal injury. This
product must be grounded. Connect only to a dedicated 120
VAC, 60 Hz circuit protected by a minimum 15 Amp
Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage
Circuit-Breaker (ELCB).
Do not use an extension cord with the product.
NOTE: Follow local codes when determining the electrical outlet
location.
Route the electrical and install to a 120 V GFCI- or
ELCB-protected receptacle. The electrical outlet should be located
within 12 (30.5 cm) of the toilet to accommodate the length of
the power cord.
2. Preparation
Remove the existing toilet seat.
Turn off the water supply to the toilet.
Flush the toilet to relieve any pressure from the water supply
hoses.
Position a container under the fill valve to catch any excess water.
Disconnect the water supply hose from the toilet fill valve.
Supply Stop
GFCI-Protected
Receptacle
Kohler Co. 5 1054180-2-E