1. Install the Spout
CAUTION: Risk of internal seal damage. Loosen the spout
setscrew with a 5/32 hex wrench prior to installing the spout.
CAUTION: Risk of internal seal damage. Do not use
petroleum-based lubricants. If the spout will not slide over the
tubing, use soapy water or silicone-based lubricant.
Threaded Spouts
Remove the temporary nipple from the bath elbow.
Apply thread sealant and install a 1/2 NPT nipple to extend
4-1/2 (11.4 cm) beyond the finished wall.
Apply a bead of plumbers putty or other sealant around the
spout base according to the manufacturer’s instructions. Leave a
small gap free of putty or other sealant at the bottom of the
spout.
Apply thread sealant to the nipple threads and install the spout
to the nipple.
Carefully tighten with a clean strap wrench.
Remove all excess putty.
Slip-Fit Spouts:
Remove the temporary nipple from the bath elbow.
Apply thread sealant and install a 1/2 copper tube to extend
from 2-1/8 (5.4 cm) to 3-1/2 (8.9 cm) beyond the finished wall.
Smooth the edges of the copper tubing.
Loosen the setscrew with a 5/32 hex wrench.
4-1/2"
(11.4 cm)
Threaded Spouts
Apply plumbers putty.
Nipple
2-1/8" (5.4 cm) to
3-1/2" (8.9 cm)
Slip-Fit
Spouts
Apply plumbers putty
5/32" Hex Wrench
Copper Tube
Setscrew
1018257-2-B 4 Kohler Co.