Kohler Bath with Airjets 1199249-2-A User Manual Page 20

  • Download
  • Add to my manuals
  • Print
  • Page
    / 64
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 19
Troubleshooting (cont.)
Symptoms Probable Causes Recommended Action
7. Blower motor runs but no
air bubbles are formed.
A. Blower air inlet is blocked. A. Clean blower air inlet.
B. Airjets are clogged. B. Use a small between-the-teeth
dental brush and white vinegar.
Dip the brush in the vinegar, brush
the hole, rinse the brush in clean
water, and then use the wet rinsed
brush to rinse the hole.
C. Check valve does not work. C. Replace the check valve.
D. Blower motor does not work. D. Replace the blower motor.
E. Control does not work. E. Replace the control.
8. Blower motor operates,
air bubbles are formed,
zone controls work, but
variable speed feature
does not work.
A. Blower air inlet is blocked. A. Clear blower air inlet.
B. Loose, disconnected, or
damaged wiring harness.
B. Check wiring for proper
connections. Replace the wiring
harness if necessary.
C. User keypad does not work. C. Replace the user keypad.
D. Blower motor does not work. D. Replace the blower motor.
E. Control does not work. E. Replace the control.
9. Blower motor won’t turn
off when the Power icon
on user keypad is
pressed.
A. User keypad does not work. A. Replace the user keypad.
B. Loose, disconnected, or
damaged wiring harness.
B. Check wiring for proper
connections. Replace the wiring
harness if necessary.
C. Control does not work. C. Replace the control.
10. A zone does not produce
air bubbles but another
zone operates normally.
A. Zone is not selected. A. Select the zone according to the
instructions in the Operating
Instructions section.
B. Butterfly valve does not work. B. Replace the butterfly valve.
C. Loose, disconnected, or
damaged wiring harness.
C. Check wiring for proper
connections. Replace the wiring
harness if necessary.
D. User keypad does not work. D. Replace the user keypad.
E. Control does not work. E. Replace the control.
11. Surge mode does not
work.
A. User keypad does not work. A. Replace the user keypad.
B. Control does not work. B. Replace the control.
12. Water spillage or damage
observed under the bath.
A. Drain or overflow leaking. A. Repair or replace the drain
assembly according to the
manufacturer’s instructions.
B. Wall, deck, and/or shower door
is improperly sealed.
B. Apply silicone sealant at the seams
between the bath and the wall,
deck, or door.
C. Cracked piping or air channels. C. Refer to the manufacturer.
13. Bath does not purge
automatically.
A. Level sensor wires are
disconnected.
A. Connect the level sensor wires.
Chromatherapy (if equipped)
Symptoms Probable Causes Recommended Action
14. Chromatherapy lights do
not work.
A. Loose, disconnected or damaged
wiring/connections.
A. Check wiring for proper
connections. Replace wiring if
necessary.
B. Control does not work. B. Replace control.
15. Chromatherapy does not
cycle.
A. Chromatherapy harness
assembly does not work.
A. Replace the chromatherapy harness
assembly.
1199249-2-A 20 Kohler Co.
Page view 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 63 64

Comments to this Manuals

No comments