Troubleshooting (cont.)
Troubleshooting Table
Symptoms Probable Cause Recommended Action
B. If the above recommended
action does not correct the
symptom, the interface or valve
requires servicing.
B. Contact your Kohler Co.
Authorized Service Representative.
5. Continuous flow. A. System will not switch off. A. Turn off the water and power
supply and contact your Kohler Co.
Authorized Service Representative.
6. Only cold water flows
from the outlets.
A. Hot water supply is either not
turned on or not connected to
the valve inlet.
A. Check if the hot water supply is
turned on and connected to the
valve inlet.
B. Hot water inlet is blocked. B. Check the hot water inlet screen for
blockage. Clean or replace the inlet
screen. Refer to the Valve
Homeowners Guide.
C. The hot water supply is
exhausted.
C. Allow time for the water heater to
come up to temperature.
D. If none of the recommended
actions for the above issues
correct the symptom, the valve
requires servicing.
D. Contact your Kohler Co.
Authorized Service Representative.
7. Fluctuating or reduced
flow rate. Valve is
functioning properly.
A. Valve inlets may be blocked. A. Check the valve inlets for blockage
or debris. Clean the inlet screens.
Refer to the Clean the Inlet
Screens section in the Valve
Homeowners Guide.
B. Fittings/Spray faces may be
blocked.
B. Clean the spray faces and any
screens in your fittings.
C. Water outlet pressure is low. C. Check that the flow rate is at or
above the minimum rate required.
Refer to Specifications section in
the Valve Homeowners Guide.
D. Fluctuating supply pressure. D. Verify that the dynamic inlet
pressures are within specifications.
Refer to Specifications section in
the Valve Homeowners Guide.
E. Water supply temperatures are
not within the recommended
range.
E. Check if inlet water temperatures
are within the recommended range.
8. Blend temperature drift or
temperature cycling.
A. Fluctuating water supply
temperature.
A. Check the inlet temperature
differentials and verify they are
sufficient. Refer to Specifications
section in the Valve Homeowners
Guide.
B.
Pressure difference greater than
5 psi (34.5 kPa) between the hot
and cold supply lines.
B. Install pressure regulators to bring
the supplies within 5 psi (34.5 kPa)
of each other.
C. If none of the recommended
actions for the above issues
correct the symptom, the valve
requires servicing.
C. Contact your Kohler Co.
Authorized Service Representative.
1143086-2-D 10 Kohler Co.