TROUBLESHOOTING CHART
The troubleshooting guide below is mean to for general aid only. All fittings in this toilet except for the piston nut are preset
by the manufacturer to prevent adjustment. Any attempt to adjust the fittings (except the piston nut and winterizing) may
damage the toilet. Such adjustments for modifications of this product are not normal usage and will void the warranty.
For proper trip lever adjustment procedures, refer to Gap Clearance on Page 6 in these instructions. Any problems not
covered in this chart should be referred to your installer/dealer.
SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION
1. No flush.
A. Supply stop closed. A. Fully open supply stop.
B. Trip lever loose. B. Tighten trip lever nut (turn
counterclockwise to tighten).
C. Trip lever does not actuate piston. C. Adjust piston nut (refer to Page
6).
D. Obstruction within water inlet
components.
D. Replace inlet components (refer to
installer/dealer for assistance).
E. Screen adapter is clogged. E. Disassemble screen adapter and
clean the screen with a medium to
hard bristle brush. (Refer to
installer/dealer or Screen Cleaning,
on Page 6.) Replace the screen if
necessary.
2. Poor flush.
A. Bowl rim holes clogged. A. Clean under bowl rim.
B. Trapway or drain line clogged. B. Plunge bowl, auger trap, auger
drain to clear blockage.
C. System not pressure charged. C. Adjust piston nut for proper
actuation arm gap (refer to Page
6).
D. Supply stop not opened. D. Fully open supply stop.
E. Drain line vent clogged. E. Refer to installer/dealer for
assistance.
F. Screen adapter is clogged. F. Disassemble screen adapter and
clean the screen with a medium to
hard bristle brush. (Refer to
installer/dealer or Screen Cleaning,
on Page 6.) Replace the screen if
necessary.
3. Bowl water
continues to flow or
tank fill water will not
shut off
A. Piston assembly not seating
properly.
A. Adjust gap between trip lever and
piston actuation arm (refer to
Page 6).
shut
off
.
B. Piston actuation arm binding. B. Repair or replace actuation arm
(refer to installer/dealer for
assistance).
C. Pressure regulator not working. C. Replace unit (refer to
installer/dealer for assistance).
Page view 6