1. Roughing-In Dimensions
X=the distance from the centerline of the spout inlet base to the
front of the spout base plus 1/2 (2.5 cm).
Install or relocate the water supplies as needed.
NOTE: Reinforcing material may be required if the deck or rim is
thin. Install 1/2 exterior grade plywood before proceeding.
The diameter of the spout hole should be 1-1/8 (2.9 cm)
maximum.
NOTE: For installations to be covered with tile, the tile thickness
must not exceed 1-1/4 (3.2 cm).
X
X
7/8" D
5/8" OD Tubing
(1/2" Nominal)
1/2" (1.3 cm) Min.±
2-1/8" (5.4 cm) Max.
Deck Thickness
1/8" (3 mm) Min.±
2-1/8" (5.4 cm) Max.
Rim Thickness
Kohler Co. 3 1010568-2-B