Kohler K-6228-C12-VS Installation Guide Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
7. Adjust the Valve - Left Handle
IMPORTANT! Perform these steps when the handle will be located on the left side of
the spout.
CAUTION: Risk of property damage. The water must be shut off before performing
these steps.
Shut off the water supply.
Remove the plaster guard/retaining ring tool.
Position a bucket at the spout outlet, then open the valve handle to relieve water
pressure. Leave the handle open.
Loosen the threaded retaining ring using the plaster guard/retaining ring tool
until it disengages from the mixer valve body.
Pull out the valve body. The plaster guard/retaining ring tool can be threaded
onto the valve body to get a better grip on the valve body when pulling it out.
Rotate the valve body 180 degrees from the original position. This allows the
handle to move up when turning the water on.
Verify the O-rings on both the valve body and the mixer valve are undamaged.
Verify the spring plunger is installed and is flush with the surface of the valve
body.
Reinstall the valve body into the mixer valve and fully seat the valve body into
the mixer valve.
CAUTION: Risk of property damage. At the maximum valve body extension, a
detent will be encountered. To avoid leakage, do not extend the valve beyond this
detent. If the valve body needs to be extended further, installation of the deep
Threaded Retaining Ring
Anneau de retenue fileté
Anillo de retención roscado
180˚
Plaster Guard/Retaining Ring Tool
Renfort en plâtre/Outil d'anneau de retenue
Herramienta para protector de yeso/anillo de retención
Valve Body
Corps de valve
Cuerpo de válvula
O-Rings
Joints-toriques
Arosellos
Spring Plunger
Plongeur de Ressort
Émbolo de resorte
1095311-2-H 16 Kohler Co.