16. Chromatherapy Light Operation
NOTE: These directions pertain to the use of the mounted control switch only. For more information, see
the Using the Remote Control section.
If the chromatherapy lights are turned off, press the button on the chromatherapy control switch
(located next to the pump control switch). The chromatherapy lights will begin to cycle through
each of the colors (sweep mode).
When the chromatherapy lights are in sweep mode, you can lock in one color light by pressing the
chromatherapy control switch.
When an individual color is locked in, press the chromatherapy control switch to turn the
chromatherapy lights off.
Troubleshooting Procedures
Troubleshooting Table
For warranty service, contact your dealer or wholesale distributor. This Troubleshooting Guide is for general
aid only. Contact a Kohler Authorized Service Representative or a qualified electrician to correct all electrical
problems. For warranty service, contact your dealer or wholesale distributor.
Symptoms Probable Causes Recommended Action
1. Green light in
On/Off control
switch flashes before
the bathing well is
full of water.
A. Spout fills directly into
overflow channel.
a. Adjust/reinstall the spout
to fill directly into the
bathing well. Refer to the
installer/dealer.
B. One or both butterfly
valves do not work.
b. Check the butterfly valve
wiring or replace the
butterfly valves. Refer to
the installer/dealer.
C. Control does not work. c. Check the wiring or
replace the control. Refer
to the installer/dealer.
2. Product does not
start.
A. No power to unit. a. Turn on the power to the
unit, or correct the source
of the power loss. Refer to
the installer/dealer.
B. Water does not cover the
overflow channel sensors.
b. Fill the bathing well until
water flows over the
bathing well rim, into the
overflow channel, and
covers the overflow
channel sensors.
Suggested fill level is to
the drain overflow.
C. On/Off control switch
does not light up or flash
when the unit is running
or filled as required.
c. Check the wiring or
replace the On/Off
control switch. Refer to
the installer/dealer.
D. Pump/motor does not
work.
d. Rebuild or replace the
pump/motor. Refer to the
installer/dealer.
E. Control does not work. e. Check the wiring or
replace the control. Refer
to the installer/dealer.
1054216-2-A 16 Kohler Co.