Troubleshooting Procedures (cont.)
Symptoms Probable Causes Recommended Action
7. Chromatherapy
lights do not work.
A. Damaged wiring harness. a. Check the wiring or
replace the control. Refer
to the installer/dealer.
B. Control does not work. b. Replace wiring harness.
Refer to the
installer/dealer.
8. Remote control does
not work.
A. Batteries improperly
installed or dead.
a. Replace the batteries.
B. Control does not work. b. Replace wiring harness.
Refer to the
installer/dealer.
C. Remote control is not
programmed correctly.
c. See homeowners guide or
service manual.
D. Remote control does not
work.
d. Replace the remote
control.
E. Control switch does not
work.
e. Replace the control.
9. Water does not
reach bath rim upon
filling.
A. No power to the unit. a. Turn on the power.
B. Level probe wires loose. b. Check/reconnect wires.
C. Butterfly valves does not
work.
c. Check wiring; replace
butterfly valves if
necessary.
D. Control switch does not
work.
d. Replace control.
1054216-2-A 18 Kohler Co.