Troubleshooting Procedures (cont.)
Symptoms Probable Causes Recommended Action
B. Control does not work. B. Replace wiring harness. Refer to
the installer/dealer.
C. Remote control is not
programmed correctly.
C. See homeowners guide or service
manual.
D. Remote control does not work. D. Replace the remote control.
E. Control switch does not work. E. Replace the control.
9. Water does not reach bath
rim upon filling.
A. No power to the unit. A. Turn on the power.
B. Level probe wires loose. B. Check/reconnect wires.
C. Butterfly valves does not work. C. Check wiring; replace butterfly
valves if necessary.
D. Control switch does not work. D. Replace control.