7. Install the Control Amplifier
WARNING: Risk of electric shock. Connect the control amplifier to a properly grounded,
grounding-type receptacle protected by a Ground-Fault Circuit-Interrupter (GFCI) or Residual
Current Device (RCD). Do not remove the grounding pin from the plug or use a grounding adapter.
Remove the control amplifier from the box. Do not remove the mounting bracket from the control
amplifier.
IMPORTANT! Keep insulating materials away from the control amplifier. Provide an unobstructed air
space around the control amplifier to permit cooling.
With the control amplifier located flush or recessed from the studs, use the wood screws provided
to secure the control amplifier to the framing. You can also use the anchors provided to secure the
control amplifier to a finished wall material other than wood.
NOTE: To make wiring connections more accessible, temporarily secure the control amplifier with one
screw on each side. This allows the control amplifier to tilt forward, making the wiring connections more
accessible. Secure the control amplifier with the remaining screws once wiring connections are made.
Remove the cover from the control amplifier by removing the four screws. Retain for reinstallation.
NOTE: The transducer terminals and wires are numbered to identify the correct connections. When
required, the control amplifier can be removed to aid in the wire connection process.
Securely attach the transducer wires to the transducer terminals - the white with black wires are the
positive (+) leads.
If equipped, connect the optional chromatherapy connector to the chromatherapy terminal.
Connect the user interface connector to the user interface terminal.
If used, connect the optional auxiliary-in RCA connectors to the auxiliary-in terminals.
Reinstall the cover to the control amplifier, and secure with the four screws.
Plug the control amplifier into the electrical outlet.
Auxiliary In
Chromatherapy
User Interface
Screws
Alternate Holes
Transducer Wiring
Screws
Control
Amplifier
Cover
Grounded Outlet