Insufcient water supply
pressure/ow for operation.
Contact local water company.
Supply pressure must be a
minimum of 0.7 bar.
Note: If other appliances are
operating, pressure may drop
below 0.7 bar.
Power
Light
Heater
Setting
Low/Medium/
High
Probable Cause Possible Remedy
Symptom
Low or No
ow
ON Any
Other outlets (e.g. toilet,
garden hose, washing
machine, etc.) drawing
water while the shower is
being used.
Turn off other appliances whilst
shower is in use.
ON Any
ON Any
Cover not tted correctly
causing Start/Stop
button not to operate.
Check Cover is cut and tted
correctly. Check services
(electrical or plumbing) are not
interfering with location of Cover.
Inlet Valve faulty. Replace.
Heater Tank excessively
scaled.
Replace. In hard water areas
consider the use of a water
softener.
ON Any Handset blocked. Remove and clean.
ON Any
ON Any
ON Any
Operation of
Temperature
Control has
little or no
effect on water
temperature.
II/IIION Handset or Inlet Filter
blocked.
Remove and clean.
Inlet Valve faulty. Replace.
Heater Tank failure. Replace.
Microswitch failure. Replace.
II/IIION
II/IIION
II/IIION
Water supply pipework or
inlet lter restricted by a
blockage or partial blockage.
Flush supply pipe. Clean Inlet
Filter.