WARNING: Risk of property damage. Allow a minimum of 12 (30.5 cm) of air space around the
steam generator at all times. This provides an area for the heat generated by the unit to dissipate.
NOTICE: When installing the control kit, allow room in the control cable for a drip loop. The drip loop
will discourage moisture from following the control cable to the steam generator.
NOTICE: The steam generator will perform best when installed as close as possible to the steam head. The
unit should be installed within 25’ (7.62 m) of the steam head.
NOTICE: For optimum performance install the steam generator below the level of the steam head.
NOTE: When possible, use 45 degree elbows. Performance will be increased when 45 degree elbows are
used.
Determine the location of the steam generator. Allow for a 12 (30.5 cm) air gap on all sides of the
generator. Allow for a drain pan.
Choose a drain pan appropriate for your installation. The drain pan is not supplied.
Tee
Steam Head
Control Cable Input
Pressure Relief Valve
Copper
Union
Shut-Off
Valve
Water
Inlet
Recommended
In-Line Water Filter
Front of Generator
(Access Panel)
Pitch toward generator.
Drain Pan
Install copper union as close
as possible to steam generator.
1053772-2-D 4 Kohler Co.