Kohler K-19480-4-BN Installation Guide Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
6. Optional Temperature Limiting Adjustment
NOTE: The water temperature does not need to be adjusted if the
maximum water temperature is below 105°F (41°C).
Lift and turn the lever handle to the full hot position.
Determine the temperature using a thermometer. If the
temperature exceeds 105°F (41°C), complete the following steps.
Using a small flat-blade screwdriver, carefully pry the plug button
off the lever handle.
Loosen the setscrew on the handle with a hex wrench, then
remove the handle and bonnet.
Note the position of the locking ring relative to the inner geared
ring.
NOTE: To avoid damage to the locking ring during removal, pry
each side of the locking ring off the inner geared ring with an equal
and even technique.
Gradually pry each side of the locking ring up off of the inner
geared ring and onto the valve stem with a flat-blade screwdriver.
Rotate the valve stem clockwise to increase temperature, or
counterclockwise to decrease temperature.
Reinstall the locking ring into the inner geared ring.
Reinstall the bonnet and handle to the faucet body.
Test the setting and make any adjustments as needed.
Plug Button
Handle
Bonnet
Inner
Geared
Ring
Locking Ring
Setscrew
Locking Ring
Inner Geared
Ring
Valve Stem
1050798-2-A 8 Kohler Co.