7. Complete the Installation
If an interface is not available, proceed to the Installation Checkout section, and Test for Leaks without an
Interface.
NOTICE: Do not plug in the power cord until all interface cables are connected.
NOTE: Make drip loops in all cables and cords.
Route the interface cable(s) in the wall from the valve location to the interface installation
location(s).
If not already installed, install the interface(s) according to the instructions packed with the product.
Attach a split boot to each interface cable.
Connect the interface cable(s) to the valve.
Press the boot over the connection and into the valve socket. If only one interface is installed, insert
a solid boot into the unused socket.
Verify there is power to the 120 V GFCI electrical outlet.
Plug the power cord into the outlet.
Slide the split boot onto the
interface cable.
Split Boot
Solid Boot
Kohler Co. 11 1145587-2-B