Kohler K-682-K-NA Installation Guide Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 64
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
Complete the Installation (cont.)
Verify all molded grommets are in place before closing the door.
Reinstall the door.
To close the door, press on the tabs until the clips snap into place.
Plug the power supply into the outlet.
12. Installation Checkout
Turn on the water supply to the valve.
Check all connections for leaks and make any adjustments as needed.
Turn on the main power supply. You should hear the valve power up and the power icon on the
user interface will be lit with a green pulsing light.
If not already completed, refer to the Digital Interface Homeowners Guide to set up the interface.
NOTE: For more information about using the user interface and its menus, refer to the user interface
Homeowners Guide.
At the main menu of the interface select SHOWER > Options > All On. This will select all connected
components and purge the air from the system.
Check for leaks and make any adjustments as needed.
Verify that the water flow is sufficient for your showering needs.
Exercising the Mixing Valve
NOTE: The maximum water temperature is limited to 120°F (49°C). The valve will automatically shut
down if the temperature exceeds 120°F (49°C).
NOTE: Mixing valves which have been in storage, installed recently, or not been used for some time,
should be exercised before running any tests or setting the maximum temperature. Follow the steps below
to exercise your valve.
Verify that both hot and cold water are connected to appropriate valve inlets.
Using the temperature adjustment screen and the dial on the user interface, adjust the temperature
from cold to hot and back to cold several times, pausing for 30 seconds at each extreme.
Check Component Functions
Using the user interface, turn on each component separately to verify that the selected component
matches the component running. Make any corrections or adjustments as needed.
Turn off the system.