9. Install the Plumbing
CAUTION: Risk of property damage. Ensure a watertight seal on the whirlpool drain.
Connect the drain to the trap according to the drain manufacturer’s instructions.
NOTICE: An access panel will simplify future maintenance.
Install the faucet valving according to the faucet manufacturer’s instructions. Do not install the
faucet trim until instructed. Open the hot and cold water supplies, and check the supply
connections for leakage.
Run water into the whirlpool, and check the drain connections for leakage.
If your whirlpool requires grip rails, install them now according to the installation instructions
packed with the grip rails.
10. Make Electrical Connections
NOTE: The whirlpool model number is printed on a label near the whirlpool pump. This label also
identifies the electrical rating of the whirlpool. All whirlpools come equipped with a wiring junction box
and will only operate at 220 V through 240 V and at 50 Hz or 60 Hz.
WARNING: Risk of electric shock. To reduce the risk of electric shock, connect the pump to a
properly grounded Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage Circuit-Breaker (ELCB).
This will provide additional protection against line-to-ground shock hazard. A 220 - 240 V, 20 A, 50/60
Hz dedicated circuit is required.
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing the
following procedures.
The whirlpool controls and system have been prewired at the factory. A licensed electrician should
make a routine service connection to the junction box.
Connect service to the junction box. The junction box contains blue, brown and green with a yellow
stripe colored wires and a ground lug.
Provide a separate equipment earthing conductor for the earth lug located inside the junction box.
The earthing conductor must not be connected to any current-carrying conductor. Follow local
electrical codes. Bond in accordance with national and local codes.
A wiring harness has been prewired at the factory, allowing communication between the keypad, all
features, and the control. No additional wiring is required, but ensure that all wires are securely
fastened.
Ground (Green with
Yellow Stripe)
Blue
Supply
60 Hz 50 Hz From Control
L1 L1 Brown
L2 N Blue
Electrician to
provide suitable
strain relief.
The junction box should be
wired as shown.
Bond in accordance with
national and local codes.
Wire
Connectors
From Control
Brown
Heater (models may
vary) T-style (shown)
or inline (not shown)
Heater Electrical Cord
Wiring
Harness
Junction
Box
Control
Pump
Electrical
Cord