7. Install the Drain Control
CAUTION: Risk of poor product performance. Location of the cable drain control on the faucet deck
is critical to product performance. Make sure the 27 (68.6 cm) control body will reach the sink drain
before the cable drain control is installed.
Remove the control flange from the control housing and apply a ring of plumbers putty or other
sealant around the bottom of the control flange according to the putty manufacturer’s instructions.
Assemble the flange nut, plastic washer and gasket to control housing. The distance between the top
of the control housing and gasket must be larger than the faucet deck thickness.
From under the sink, lift the control housing up to faucet deck and turn the control flange until
tight.
Align position of control housing as previously determined.
Push the control flange onto the sink.
Tighten the flange nut and remove excess putty or sealant.
8. Complete the Strainer Installation
Apply thread sealant tape to the control body.
Slide the nut onto the tailpiece and insert the small gasket.
Thread the tailpiece to the control body and tighten the nut securely with a wrench.
Apply
Plumbers
Putty.
Control
Flange
Control Knob
Indicator
Control Knob
Flange
Nut
Plastic
Washer
Control
Housing
Gasket
Control Body
Gasket
Tailpiece
Nut
Cable
(Assembled
to Control)