Troubleshooting
Symptoms Probable
Causes
Recommended Action
1. No water
flow.
A. Filter is
plugged.
A. Clean or replace the filter.
B. Sensor eyes
are dirty.
B. Wipe the sensor eyes with a
damp soft cloth. Wipe dry with a
dry soft cloth.
C. Water not
turned on.
C. Verify that the water supply is
turned on and that pressure is at
least 20 psi (137 kPa).
D. Incorrect
installation.
D. Verify that the faucet is
mounted as instructed in the
installation guide. Ensure that the
sensor eyes are above the rim of
the lavatory. Refer to the
installation instructions.
E. The aerator
is plugged.
E. Remove and clean the aerator.
For calcium/mineral deposits, soak
the plastic insert in a 50:50 mix of
water and vinegar. Soak only the
plastic insert.
F. Sensor eyes
are scratched.
F. Replace the sensor assembly.
G. A flex hose
is kinked.
G. Check the flex hoses to make
certain they are not kinked. If a
flex hose is kinked, disconnect it,
straighten, and reconnect.
H. Batteries
have just been
replaced.
H. Wait 2 minutes after replacing
batteries as the sensor cycles
through the automatic sensing
distance.
I. Battery life
expired.
I. Remove faucet from body and
replace batteries. Use two standard
AAA batteries.
J. Bleed hole
in diaphragm
is plugged or
debris exists
on the seal.
J. Clean or replace the diaphragm.
K. Solenoid is
broken.
K. Order a new solenoid service
kit.
Kohler Co. 5 1102759-2-B