Kohler K-1357-VB-0 Installation Guide Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
Troubleshooting
This troubleshooting guide is for general aid only. For service and installation issues or concerns, call
1-800-4KOHLER.
Troubleshooting Table
Symptom Probable Cause Recommended Action
1. No sound; no experiences
are functioning.
A. Power to the control amplifier is
off.
A. Reset the circuit breaker to the
control amplifier, then check the
electrical power supply and
connections.
B. The control amplifier must be
reset.
B. If the red LED on the control
amplifier is not blinking, unplug the
control amplifier for 30 seconds,
then plug in and restart.
C. The control amplifier does not
work.
C. If the red LED on the control
amplifier is still not blinking
following restart, replace the control
amplifier.
D. The user interface cable
connections are loose or
damaged.
D. Inspect the cable for loose
connections or damage. Tighten the
connections or replace the cable as
needed.
E. The experiences data module
connection is loose or damaged.
E. Inspect the data module for loose
connection or damage. Tighten the
connection or replace the module as
needed.
F. The user interface does not
work.
F. Replace the user interface.
G. An experience has not been
selected on the user interface.
G. Select an experience.
H. The vibracoustic intensity is
muted on the user interface.
H. Touch the [Mute] icon on the user
interface to turn off the mute
setting.
2. The music is distorted
(undesirable resonance)
when the vibracoustic
functions are on.
A. The intensity setting is too high
on the user interface.
A. Turn down the intensity setting on
the user interface.
B. The transducers on the back
surface of the bath are in direct
contact with framing, joists, or
other materials.
B. Remove or reposition any materials
that are making direct contact with
the transducers.
C. One or more of the transducers
on the back surface of the bath
are loose.
C. Rotate the loose transducer(s)
clockwise with your fingers until
tight. Do not overtighten.
D. The bath is making direct
contact with framing, joists, or
other materials.
D. Identify the point of contact and
correct it. The bath must not make
contact with any framing or support
materials.
3. The user interface does
not light up and does not
work.
A. Power to the control amplifier is
not on.
A. Reset the circuit breaker to the
control amplifier, then check the
electrical power supply and
connections.
B. The control amplifier must be
reset.
B. If the red LED on the control
amplifier is not blinking, unplug the
control amplifier for 30 seconds,
then plug in and restart.
C. The control amplifier does not
work.
C. If the red LED on the control
amplifier is still not blinking
following restart, replace the control
amplifier.
Kohler Co. 15 1181167-2-E
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 55 56

Comments to this Manuals

No comments