Before You Begin (cont.)
The variety of installations possible with this bath may require framing procedures other than those
described in this manual.
Confirm adequate mounting and connection space for the faucet specified for your installation.
For Remote Installations
When mounting the blower motor and check valve in a remote location, choose a space as close to
the bath as possible to maximize bath performance. Pay attention to the following requirements and
recommendations:
The blower motor must be mounted horizontally at least 2 (5.1 cm) above the floor. Do not mount
the blower motor with the blower motor discharge pointing up.
1-1/2 PVC or equivalent rigid piping should be used.
The piping installation must meet the requirements of local plumbing or building codes. Ensure that
the installation does not reduce the fire rating of any walls. Piping must be supported at intervals
along the length in accordance with local codes.
Ensure that the blower motor location is clean and free of dust or debris.
If appropriate, install an additional access panel for blower motor maintenance.
The 18 AWG minimum power cable to the blower motor must meet the requirements of the
applicable electrical or building codes. Ensure that the installation does not reduce the fire rating of
any walls.
The power cord must be supported at intervals along the length in accordance with local codes.
Power cords may not rest on surfaces or floors that are subject to flooding.
All material needed for the relocation must be supplied by the installer.
Additional tools and materials:
Electrician pliers.
Assorted screwdrivers.
Adjustable wrench.
Drill and bits to install the blower mounting fasteners.
18 AWG non-metallic sheathed cable, two conductors with ground, with support clips, as required.
One (1) 4 (10.2 cm) x 2 (5.1 cm) electrical junction box with cover, gasket, and mounting screws.
Three (3) strain reliefs. One must fit the blower motor cover with standard NPT (National Pipe
Thread) threads. The other two must fit the holes in the new junction box.
Six (6) wire connectors (wire nuts or equivalent).
1-1/2 (3.8 cm) PVC or other rigid pipe with: fittings, unions, PVC cement (or equivalent fastening
method), and support clips, as required.
Four (4) fasteners (such as flathead wood screws or concrete anchors) to mount the blower motor.
Solid copper 8 gauge bonding wire, 36 (91.4 cm).