TP-5695 12/93 Scheduled Maintenance 3-23
Wattage Requirements
Iftheratedcapacityofthegeneratorsetisexceeded,the
circuitbreakerlocatedonthecontrollerwilltriptoprotect
the generator against damage. Tripping could be
caused by a short in the AC circuit in the craft or simply
by having too many appliances on at the same time
resulting in an overload condition. If the circuit breaker
trips, the set may continue running but there will be no
AC output to the protected circuit. Before resetting the
circuitbreaker,turnoffsomeoftheappliancesandlights
inside the craft to bring the load down within the rated
limitsoftheset.Ifthisisdoneandthecircuitbreakertrips
again after being reset, see a qualified electrician.
For more information regarding generator set capacity,
see InstallationGenerator Selection and Wattage
Requirements.
Generator Service
General
Under normal conditions generator service will not be
requiredon aregularbasis. Ifoperatingunder dustyand
dirty conditions, use DRY compressed air to blow dust
outofthegeneratoratfrequentintervals.Dothiswiththe
generator set operating and direct the stream of air in
through the cooling slots at the end of the generator.
The end bracket bearing should be replaced every
10,000 hours of operation. Have bearing replaced
sooner if bearing inspection indicates excessive rotor
end play or bearing damage from corrosion or heat
buildup.Theend bracket bearing is sealed andrequires
no additional lubrication. All generator service must be
performed by an authorized service dealer/distributor.