IMPORTANT INSTRUCTIONS
WARNING: When using electrical products, basic precautions should always be followed, including
the following:
DANGER: Risk of electric shock. Connect only to circuits protected by a Ground-Fault
Circuit-Interrupter (GFCI) or Earth-Leakage Circuit Breaker (ELCB). Grounding is required. The unit
should be installed and grounded by a qualified service representative.
WARNING: Risk of electric shock. A licensed electrician should route all electrical wiring.
WARNING: Risk of electric shock. Disconnect power before servicing.
WARNING: Unauthorized modification may cause poor performance of the valve. Do not make
modifications to the valve as this could adversely affect the performance of the valve and void the
warranty. Kohler Co. shall not be liable under its warranty or otherwise for personal injury or damage
caused by any such unauthorized modification.
WARNING: Risk of injury or property damage. Please read all instructions thoroughly before
beginning installation.
NOTICE: Follow all plumbing, electrical, and building codes.
NOTICE: Provide generous, unrestricted service access to the valve. Provide access for servicing the
valve and interface. This access must be located immediately next to the valve. Refer to the roughing in
information.
Specifications
Pressures
Maximum Static Pressure 125 psi, 862 kPa, 8.6 bar
Supply Pressure Differential* Max 5 psi, 34.5 kPa, 0.34 bar (Equal pressures recommended.)
Minimum Flow Rate 1.6 gpm (Less than 72 psi dynamic pressure.)
6 lpm (Less than 500 kPa maintaining pressure.)
2.1 gpm (Greater than 72 psi dynamic pressure.)
8 lpm (Greater than 500 kPa maintaining pressure.)
Temperatures
Programmable Temperature Max 120°F (49°C) Min 79°F (26°C) Full cold may also be selected.
Default Temperature at Start-up 102°F (39°C)
Minimum Mixed Temperature
Differential from Hot Supply
3.6°F (2°C)
Optimum Thermostatic Control Range 86°F (30°C) to 120°F (49°C)
Temperature Stability at Recommended
Supply Conditions
+/- 1.6°F (1°C)
Ambient Temperature Greater than 34°F (1°C), Max 104°F (40°C)
Maximum Relative Humidity 95% non-condensing
Electrical
Electrical Service 100-240 VAC, 50-60 Hz, 1.5 A
User Interface Cable Length (supplied) 30 ft (9.14 m)
* In commercial applications where there is a large difference in hot and cold supply pressures or frequent
fluctuation in either supply line is anticipated, it is strongly recommended that pressure regulators be
installed.