Product Information (cont.)
Features
Factory assembled components include a blower motor, air harness, control, check valve, butterfly valves,
chromatherapy lights (certain models), electrical harnesses, and an illuminated user keypad. Other than
power wiring and plumbing connections, no assembly is required.
Tools and Materials
Prepare the Blower (Remote Site)
NOTICE: The blower motor and the check valve must be relocated together. Do not relocate one
without the other.
NOTE: This bath can be installed as received or with the blower motor and check valve relocated to
another location. Refer to the appropriate sections throughout this manual for instructions related to your
particular installation. Read this section before relocating your blower.
All material needed for the relocation of the blower motor must be supplied by the installer.
Additional tools and materials you will need to relocate the blower motor:
Electrician pliers
Assorted screwdrivers
Adjustable wrench
Drill and bits to install the blower mounting fasteners
18 AWG non-metallic sheathed cable, two conductors with ground, with support clips, as required
One 4 (102 mm) x 2 (51 mm) electrical junction box with cover, gasket, and mounting screws
Three strain reliefs - one must fit the blower motor cover with standard National Pipe Thread (NPT)
threads. The other two must fit the holes in the new junction box.
Six wire connectors (wire nuts or equivalent)
1-1/2 PVC or other rigid pipe with fittings, unions, PVC cement (or equivalent fastening method),
and support clips, as required
Four fasteners (such as flathead wood screws or concrete anchors) to secure the blower motor
Solid copper 8-gauge bonding wire, 36 (914 mm)
Relocate the blower and check valve as close as possible to the bath to maximize performance. Do
not relocate the blower and check valve more than 15’ (4.5 m) from the bath.
Silicone Sealant
Plus:
• Conventional woodworking
tools and materials
• Drop cloth
• Metal shims
• 2x4s
Measuring Tape
Pencil Tin Snips
Safety Glasses
Level
Pipe Wrench
Kohler Co. 3 1199249-2-B