Kohler K-1665-G Installation Guide Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
4. Installation - Wallboard Style
Lift the light fixture into place. The bottom of the fixture (large
flat area) should be flush with the bottom of the ceiling joists.
Make sure the light fixture is flat and level.
Extend the mounting rods until they are tight against the joists.
Pound the spike into the joist.
Fasten a nail or wood screw into the nail hole in each rod.
Connect the Wires
Remove the cover plate from the junction box.
Remove one small knockout slug from the junction box.
Pass 110 V, 60 Hz supply cable through the knockout hole and
secure with a strain relief bushing (not provided).
NOTE: Use UL listed wire nuts to connect the wires.
Connect the ground fixture (green) wire to the ground supply
line.
Connect the white wires to each other.
Connect the black wires to each other.
Replace the cover plate.
Joists
Spike
Wirenut
Cover
Nail
Hole
Junction
Box
Kohler Co. 7 1015878–2–B