Troubleshooting (cont.)
Airjet System Troubleshooting Table
Symptoms Probable Causes Recommended Action
5. Blower motor operates,
air bubbles are formed,
zone controls work, but
variable speed feature
does not work.
A. Blower air inlet is blocked. A. Clear blower air inlet.
B. Loose, disconnected, or
damaged wiring harness.
B. Check wiring for proper
connections. Replace the wiring
harness if necessary.
C. Bubble control does not work. C. Replace the bubble control.
D. Blower motor does not work. D. Replace the blower motor.
E. User interface does not work. E. Replace the user interface.
6. Blower motor won’t turn
off when the power icon
on user interface is
touched.
A. Loose, disconnected, or
damaged wiring harness.
A. Check wiring for proper
connections. Replace the wiring
harness if necessary.
B. Bubble control does not work. B. Replace the bubble control.
C. User interface does not work. C. Replace the user interface.
7. A zone does not produce
air bubbles but another
zone operates normally.
A. Zone is not selected. A. Select the zone according to the
instructions in the Operating
Instructions section.
B. Butterfly valve does not work. B. Replace the butterfly valve.
C. Loose, disconnected, or
damaged wiring harness.
C. Check wiring for proper
connections. Replace the wiring
harness if necessary.
D. Bubble control does not work. D. Replace the bubble control.
E. User interface does not work. E. Replace the user interface.
8. Water spillage or damage
observed under the bath.
A. Drain or overflow leaking. A. Repair or replace the drain
assembly according to the
manufacturer’s instructions.
B. Wall, deck, and/or shower door
is improperly sealed.
B. Apply silicone sealant at the seams
between the bath and the wall,
deck, or door.
C. Cracked piping or air channels. C. Contact Kohler Co. using the
information on the back page.
9. Bath does not purge
automatically.
A. Level sensor wires are
disconnected.
A. Connect the level sensor wires.
B. User interface cable connections
are loose or damaged.
B. Inspect the cables between the user
interface, heated surface control,
bubble control, and control
amplifier. Secure connections or
replace cables as needed.
C. Bubble control does not work. C. Replace the bubble control.
D. Blower motor does not work. D. Replace the blower motor.
(Optional) Chromatherapy Troubleshooting Table
Symptom Probable Cause Recommended Action
1. Chromatherapy lights do
not work.
A. Power to the control amplifier is
off.
A. Reset the circuit breaker to the
control amplifier, then check the
electrical power supply and
connections.
B. Control amplifier must be reset. B. If the red LED on the control
amplifier is not blinking, unplug
the control amplifier for 30
seconds, then plug in and restart.
C. Chromatherapy feature has not
been selected on the user
interface.
C. Select the Chromatherapy feature
on the user interface.
Kohler Co. 21 1212245-2-B