Kohler K-2971-KS-NA Installation Guide Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
8. Complete the Finished Wall
CAUTION: Risk of product damage. This valve contains
plastic and rubber components that may become damaged if
soldering heat is applied directly to the valve body.
CAUTION: Risk of damage to the K-2971-KS valve
assembly. When using the K-2971-KS HiFlow Valve in a
fiberglass or acrylic installation, use the Thin Wall Installation
Kit (88526).
NOTE: Thick wall installations are typically tile, plaster, marble, or
similar materials. Thin wall installations are typically fiberglass and
acrylic.
NOTE: Do not adjust the maximum water temperature at this time.
Thick Wall Installation
Provide a 5-9/16 (14.1 cm) diameter hole in the wall material.
The flat front surface of the plaster guard must be flush with the
finished wall.
Complete the finished wall.
Plaster Guard
Dome
Finished
Wall
5-9/16" D.
(14.1 cm)
1/2"
(1.3 cm)
2-1/4" to 3"
(5.7 to 7.6 cm)
Rough-In Depth
Attachment Hole
Backing Plate
Backing Plate
Plaster Guard
Outer Ring
Valve Stem
Dome
Finished
Wall
Plaster
Guard
2-1/4" (5.7 cm)
Rough-In Depth
4" D. (10.2 cm)
Kohler Co. 11 1150733-2-A
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 39 40

Comments to this Manuals

No comments